Skip to content
Pemindahan Teknologi MPOB

Pemindahan Teknologi MPOB

(MPOB Transfer of Technology)

Pemindahan Teknologi MPOB
  • Siri Pemindahan Teknologi
    • Teknologi Baru Tahun 2024
    • 2021-2023
      • Teknologi Tahun 2023
      • Teknologi Tahun 2022
      • Teknologi Tahun 2021
    • 2011 – 2020
      • Teknologi Tahun 2020
      • Teknologi Tahun 2019
      • Teknologi Tahun 2018
      • Teknologi Tahun 2017
      • Teknologi Tahun 2016
      • Teknologi Tahun 2015
      • Teknologi Tahun 2014
      • Teknologi Tahun 2013
      • Teknologi Tahun 2012
      • Teknologi Tahun 2011
    • 2000 – 2010
      • Teknologi Tahun 2010
      • Teknologi Tahun 2009
      • Teknologi Tahun 2008
      • Teknologi Tahun 2007
      • Teknologi Tahun 2006
      • Teknologi Tahun 2005
      • Teknologi Tahun 2004
      • Teknologi Tahun 2003
      • Teknologi Tahun 2002
      • Teknologi Tahun 2001
      • Teknologi Tahun 2000
    • Teknologi Tahun 1999 & Sebelumnya
  • Pengkomersilan Teknologi MPOB
  • Brosur Teknologi PORTSIM

Senarai Teknologi 2010

TT No. 442: Ganosken for Early Detection of Ganoderma Infection in Oil Palm

Diagnosis of Ganoderma infection in oil palm is based on the presence of basidiomata of the pathogen on the stem base or frond bases or roots. To conduct various studies on Ganoderma in oil palm, a Ganoderma selective medium (GSM) was developed. The medium was used to isolate the pathogen from any part of the … Read more

TS No. 92: Determination of Phosphorus Content in Biodiesel Using Inductively Coupled Plasma Optical Emission Spectrometer (ICP OES)

A weighed test portion of the sample is diluted in xylene. The solution is introduced in aerosol form into an argon plasma of the ICP OES spectrometer (Figure 1). The phosphorus content is calculated with reference to a set of calibration solution prepared. The wavelengths used are 213.6 nm and 178.3 nm. Main Research: Yung … Read more

TS No. 91: Determination of Sodium, Potassium, Calcium and Magnesium Contents in Biodiesel Using Inductively Coupled Plasma Optical Emission Spectrometer (ICP OES)

The sample is diluted with kerosene using a 1:1 weight ratio. The resulting solution is directly injected into the plasma of the ICP OES spectrometer (Figure 1), and the content of Na, K, Ca and Mg is calculated with reference to a set of calibration solutions prepared. The wavelengths for the analysis of Na, K, … Read more

TS No. 90: Determination of Potassium Content in Biodiesel Using Atomic Absorption Spectroscopy (AAS)

The biodiesel sample is diluted with a xylene solution. The potassium contentof the sample is directly determine by flame atomic absorption spectoromery (Figure 1) at a wavelength of 766.5 nm with reference to a set of calibration solutions prepared from a potassium organolmetallic salt dissolved in a mixture of xylene and stabilizer. Main Research: Yung … Read more

TS No. 89: Determination of Sodium Content in Biodiesel Using Atomic Absorption Spectroscopy (AAS)

The biodiesel sample is diluted with xylene solution. The sodium content in the sample is directly determine by flame atomic absorption spectrometry (Figure 1) at the sample wavelength of 589 nm with reference to a set of calibration solutions prepared from a sodium organolmetallic salt dissolved in a mixture of xylene and stock oil. Main … Read more